@@ -719,13 +719,37 @@ static int fec_send(struct eth_device *dev, void *packet, int length)
|
|
|
break;
|
|
|
}
|
|
|
|
|
|
- if (!timeout)
|
|
|
+ if (!timeout) {
|
|
|
ret = -EINVAL;
|
|
|
+ goto out;
|
|
|
+ }
|
|
|
|
|
|
- invalidate_dcache_range(addr, addr + size);
|
|
|
- if (readw(&fec->tbd_base[fec->tbd_index].status) & FEC_TBD_READY)
|
|
|
+ /*
|
|
|
+ * The TDAR bit is cleared when the descriptors are all out from TX
|
|
|
+ * but on mx6solox we noticed that the READY bit is still not cleared
|
|
|
+ * right after TDAR.
|
|
|
+ * These are two distinct signals, and in IC simulation, we found that
|
|
|
+ * TDAR always gets cleared prior than the READY bit of last BD becomes
|
|
|
+ * cleared.
|
|
|
+ * In mx6solox, we use a later version of FEC IP. It looks like that
|
|
|
+ * this intrinsic behaviour of TDAR bit has changed in this newer FEC
|
|
|
+ * version.
|
|
|
+ *
|
|
|
+ * Fix this by polling the READY bit of BD after the TDAR polling,
|
|
|
+ * which covers the mx6solox case and does not harm the other SoCs.
|
|
|
+ */
|
|
|
+ timeout = FEC_XFER_TIMEOUT;
|
|
|
+ while (--timeout) {
|
|
|
+ invalidate_dcache_range(addr, addr + size);
|
|
|
+ if (!(readw(&fec->tbd_base[fec->tbd_index].status) &
|
|
|
+ FEC_TBD_READY))
|
|
|
+ break;
|
|
|
+ }
|
|
|
+
|
|
|
+ if (!timeout)
|
|
|
ret = -EINVAL;
|
|
|
|
|
|
+out:
|
|
|
debug("fec_send: status 0x%x index %d ret %i\n",
|
|
|
readw(&fec->tbd_base[fec->tbd_index].status),
|
|
|
fec->tbd_index, ret);
|