Jelajahi Sumber

ddr: altera: Remove unnecessary ODT mode config

There is no point in resetting the ODT setting if the write test
failed, since the code will always retry the calibration and thus
reconfigure the ODT anyway OR the code will fail calibration and
halt.

Signed-off-by: Marek Vasut <marex@denx.de>
Cc: Dinh Nguyen <dinguyen@opensource.altera.com>
Cc: Chin Liang See <clsee@altera.com>
Marek Vasut 9 tahun lalu
induk
melakukan
f3f777cdf0
1 mengubah file dengan 0 tambahan dan 1 penghapusan
  1. 0 1
      drivers/ddr/altera/sequencer.c

+ 0 - 1
drivers/ddr/altera/sequencer.c

@@ -1207,7 +1207,6 @@ rw_mgr_mem_calibrate_write_test(const u32 rank_bgn, const u32 write_group,
 			   *bit_chk == param->write_correct_mask);
 		return *bit_chk == param->write_correct_mask;
 	} else {
-		set_rank_and_odt_mask(0, RW_MGR_ODT_MODE_OFF);
 		debug_cond(DLEVEL == 2,
 			   "write_test(%u,%u,ONE) : %u != %i => %i\n",
 			   write_group, use_dm, *bit_chk, 0, *bit_chk != 0);