|
@@ -30,49 +30,54 @@ static const unsigned long baudrate_table[] = CONFIG_SYS_BAUDRATE_TABLE;
|
|
|
static void serial_find_console_or_panic(void)
|
|
|
{
|
|
|
struct udevice *dev;
|
|
|
-
|
|
|
-#ifdef CONFIG_OF_CONTROL
|
|
|
int node;
|
|
|
|
|
|
- /* Check for a chosen console */
|
|
|
- node = fdtdec_get_chosen_node(gd->fdt_blob, "stdout-path");
|
|
|
- if (node < 0)
|
|
|
- node = fdt_path_offset(gd->fdt_blob, "console");
|
|
|
- if (!uclass_get_device_by_of_offset(UCLASS_SERIAL, node, &dev)) {
|
|
|
- gd->cur_serial_dev = dev;
|
|
|
- return;
|
|
|
- }
|
|
|
-
|
|
|
- /*
|
|
|
- * If the console is not marked to be bound before relocation, bind
|
|
|
- * it anyway.
|
|
|
- */
|
|
|
- if (node > 0 &&
|
|
|
- !lists_bind_fdt(gd->dm_root, gd->fdt_blob, node, &dev)) {
|
|
|
- if (!device_probe(dev)) {
|
|
|
+ if (OF_CONTROL) {
|
|
|
+ /* Check for a chosen console */
|
|
|
+ node = fdtdec_get_chosen_node(gd->fdt_blob, "stdout-path");
|
|
|
+ if (node < 0)
|
|
|
+ node = fdt_path_offset(gd->fdt_blob, "console");
|
|
|
+ if (!uclass_get_device_by_of_offset(UCLASS_SERIAL, node,
|
|
|
+ &dev)) {
|
|
|
gd->cur_serial_dev = dev;
|
|
|
return;
|
|
|
}
|
|
|
- }
|
|
|
-#endif
|
|
|
- /*
|
|
|
- * Try to use CONFIG_CONS_INDEX if available (it is numbered from 1!).
|
|
|
- *
|
|
|
- * Failing that, get the device with sequence number 0, or in extremis
|
|
|
- * just the first serial device we can find. But we insist on having
|
|
|
- * a console (even if it is silent).
|
|
|
- */
|
|
|
+
|
|
|
+ /*
|
|
|
+ * If the console is not marked to be bound before relocation,
|
|
|
+ * bind it anyway.
|
|
|
+ */
|
|
|
+ if (node > 0 &&
|
|
|
+ !lists_bind_fdt(gd->dm_root, gd->fdt_blob, node, &dev)) {
|
|
|
+ if (!device_probe(dev)) {
|
|
|
+ gd->cur_serial_dev = dev;
|
|
|
+ return;
|
|
|
+ }
|
|
|
+ }
|
|
|
+ } else {
|
|
|
+ /*
|
|
|
+ * Try to use CONFIG_CONS_INDEX if available (it is numbered
|
|
|
+ * from 1!).
|
|
|
+ *
|
|
|
+ * Failing that, get the device with sequence number 0, or in
|
|
|
+ * extremis just the first serial device we can find. But we
|
|
|
+ * insist on having a console (even if it is silent).
|
|
|
+ */
|
|
|
#ifdef CONFIG_CONS_INDEX
|
|
|
#define INDEX (CONFIG_CONS_INDEX - 1)
|
|
|
#else
|
|
|
#define INDEX 0
|
|
|
#endif
|
|
|
- if (uclass_get_device_by_seq(UCLASS_SERIAL, INDEX, &dev) &&
|
|
|
- uclass_get_device(UCLASS_SERIAL, INDEX, &dev) &&
|
|
|
- (uclass_first_device(UCLASS_SERIAL, &dev) || !dev))
|
|
|
- panic_str("No serial driver found");
|
|
|
+ if (!uclass_get_device_by_seq(UCLASS_SERIAL, INDEX, &dev) ||
|
|
|
+ !uclass_get_device(UCLASS_SERIAL, INDEX, &dev) ||
|
|
|
+ (!uclass_first_device(UCLASS_SERIAL, &dev) || dev)) {
|
|
|
+ gd->cur_serial_dev = dev;
|
|
|
+ return;
|
|
|
+ }
|
|
|
#undef INDEX
|
|
|
- gd->cur_serial_dev = dev;
|
|
|
+ }
|
|
|
+
|
|
|
+ panic_str("No serial driver found");
|
|
|
}
|
|
|
|
|
|
/* Called prior to relocation */
|