Browse Source

ORIGEN : use absolute paths and fix tool naming

On some hosts using relative paths will cause the build to fail. This
patch sets absolute paths for the tools directory

Get rid of MSDOS style excecutable extension

Signed-off-by: Angus Ainslie <angus.ainslie@linaro.org>
Signed-off-by: Minkyu Kang <mk7.kang@samsung.com>
Angus Ainslie 13 years ago
parent
commit
a2ee7f07fa
2 changed files with 4 additions and 4 deletions
  1. 3 3
      board/samsung/origen/Makefile
  2. 1 1
      spl/Makefile

+ 3 - 3
board/samsung/origen/Makefile

@@ -41,7 +41,7 @@ OBJS	:= $(addprefix $(obj),$(COBJS) $(SOBJS))
 ALL	+=$(obj).depend $(LIB)
 
 ifdef CONFIG_SPL_BUILD
-ALL	+= tools/mk$(BOARD)spl.exe
+ALL	+= $(OBJTREE)/tools/mk$(BOARD)spl
 endif
 
 all:	$(ALL)
@@ -50,8 +50,8 @@ $(LIB):	$(OBJS)
 	$(call cmd_link_o_target, $(OBJS))
 
 ifdef CONFIG_SPL_BUILD
-tools/mk$(BOARD)spl.exe:	tools/mkv310_image.c
-	$(HOSTCC) tools/mkv310_image.c -o tools/mk$(BOARD)spl.exe
+$(OBJTREE)/tools/mk$(BOARD)spl:	tools/mkv310_image.c
+	$(HOSTCC) tools/mkv310_image.c -o $(OBJTREE)/tools/mk$(BOARD)spl
 endif
 
 #########################################################################

+ 1 - 1
spl/Makefile

@@ -110,7 +110,7 @@ all:	$(ALL-y)
 
 ifdef CONFIG_SAMSUNG
 $(obj)$(BOARD)-spl.bin: $(obj)u-boot-spl.bin
-	$(TOPDIR)/board/$(BOARDDIR)/tools/mk$(BOARD)spl.exe \
+	$(OBJTREE)/tools/mk$(BOARD)spl \
 		$(obj)u-boot-spl.bin $(obj)$(BOARD)-spl.bin
 endif