Pārlūkot izejas kodu

imx: mx6sx: Fix issue in LCDIF clock enablement

Wrong checking for the base_addr paramter with LCDIF1 and LCDIF2. Always
enter the -EINVAL return.

Signed-off-by: Ye Li <ye.li@nxp.com>
Reviewed-by: Stefano Babic <sbabic@denx.de>
Ye Li 9 gadi atpakaļ
vecāks
revīzija
9655ebdd50
1 mainītis faili ar 2 papildinājumiem un 2 dzēšanām
  1. 2 2
      arch/arm/cpu/armv7/mx6/clock.c

+ 2 - 2
arch/arm/cpu/armv7/mx6/clock.c

@@ -742,8 +742,8 @@ int enable_lcdif_clock(u32 base_addr)
 	u32 lcdif_clk_sel_mask, lcdif_ccgr3_mask;
 
 	if (is_cpu_type(MXC_CPU_MX6SX)) {
-		if ((base_addr == LCDIF1_BASE_ADDR) ||
-		    (base_addr == LCDIF2_BASE_ADDR)) {
+		if ((base_addr != LCDIF1_BASE_ADDR) &&
+		    (base_addr != LCDIF2_BASE_ADDR)) {
 			puts("Wrong LCD interface!\n");
 			return -EINVAL;
 		}