瀏覽代碼

ARM: zynq: DT: Migrate UART to Cadence binding

The Zynq UART is Cadence IP and the driver has been renamed accordingly.
Migrate the DT to use the new binding for the UART driver.

Signed-off-by: Soren Brinkmann <soren.brinkmann@xilinx.com>
Acked-by: Peter Crosthwaite <peter.crosthwaite@xilinx.com>
Acked-by: Rob Herring <robh@kernel.org>
Tested-by: Michal Simek <michal.simek@xilinx.com>

Signed-off-by: Michal Simek <michal.simek@xilinx.com>
Michal Simek 10 年之前
父節點
當前提交
8a8c46a65d
共有 1 個文件被更改,包括 4 次插入4 次删除
  1. 4 4
      arch/arm/dts/zynq-7000.dtsi

+ 4 - 4
arch/arm/dts/zynq-7000.dtsi

@@ -149,19 +149,19 @@
 		};
 
 		uart0: serial@e0000000 {
-			compatible = "xlnx,xuartps";
+			compatible = "xlnx,xuartps", "cdns,uart-r1p8";
 			status = "disabled";
 			clocks = <&clkc 23>, <&clkc 40>;
-			clock-names = "ref_clk", "aper_clk";
+			clock-names = "uart_clk", "pclk";
 			reg = <0xE0000000 0x1000>;
 			interrupts = <0 27 4>;
 		};
 
 		uart1: serial@e0001000 {
-			compatible = "xlnx,xuartps";
+			compatible = "xlnx,xuartps", "cdns,uart-r1p8";
 			status = "disabled";
 			clocks = <&clkc 24>, <&clkc 41>;
-			clock-names = "ref_clk", "aper_clk";
+			clock-names = "uart_clk", "pclk";
 			reg = <0xE0001000 0x1000>;
 			interrupts = <0 50 4>;
 		};