Add pfuze3000 voltage configuration macro for SW1AB, SW3 and VLDO1/2 according to tables 53, 57 and 62 on PF3000 datasheet. Signed-off-by: Breno Lima <breno.lima@nxp.com>
@@ -75,4 +75,9 @@ enum {
int power_pfuze3000_init(unsigned char bus);
+/* Voltage Configuration */
+#define PFUZE3000_SW1AB_SETP(x) ((x - 7000) / 250)
+#define PFUZE3000_SW3_SETP(x) ((x - 9000) / 500)
+#define PFUZE3000_VLDO_SETP(x) ((x - 8000) / 500)
+
#endif