Procházet zdrojové kódy

sunxi: power: Change A23/A33 aldo1 default voltage to 3.0V

On A23 / A33 boards aldo1 is used for VCC-IO and should be 3.0V, make this
the default.

Note that this does not cause any functional changes since all sun8i
board defconfig-s already contained: CONFIG_AXP_ALDO1_VOLT=3000 .

Signed-off-by: Hans de Goede <hdegoede@redhat.com>
Acked-by: Ian Campbell <ijc@hellion.org.uk>
Hans de Goede před 9 roky
rodič
revize
514b2d9dbb

+ 0 - 1
configs/Sinlinx_SinA33_defconfig

@@ -9,4 +9,3 @@ CONFIG_SPL=y
 # CONFIG_CMD_IMLS is not set
 # CONFIG_CMD_FLASH is not set
 # CONFIG_CMD_FPGA is not set
-CONFIG_AXP_ALDO1_VOLT=3000

+ 0 - 1
configs/ga10h_v1_1_defconfig

@@ -22,6 +22,5 @@ CONFIG_SYS_EXTRA_OPTIONS="CONS_INDEX=5"
 # CONFIG_CMD_FLASH is not set
 # CONFIG_CMD_FPGA is not set
 CONFIG_AXP_DLDO1_VOLT=3300
-CONFIG_AXP_ALDO1_VOLT=3000
 CONFIG_USB_EHCI_HCD=y
 CONFIG_USB_MUSB_HOST=y

+ 0 - 1
configs/gt90h_v4_defconfig

@@ -21,5 +21,4 @@ CONFIG_SYS_EXTRA_OPTIONS="CONS_INDEX=5"
 # CONFIG_CMD_FLASH is not set
 # CONFIG_CMD_FPGA is not set
 CONFIG_AXP_DLDO1_VOLT=3300
-CONFIG_AXP_ALDO1_VOLT=3000
 CONFIG_USB_MUSB_HOST=y

+ 0 - 1
configs/q8_a23_tablet_800x480_defconfig

@@ -21,5 +21,4 @@ CONFIG_SYS_EXTRA_OPTIONS="CONS_INDEX=5"
 # CONFIG_CMD_FLASH is not set
 # CONFIG_CMD_FPGA is not set
 CONFIG_AXP_DLDO1_VOLT=3300
-CONFIG_AXP_ALDO1_VOLT=3000
 CONFIG_USB_MUSB_HOST=y

+ 0 - 1
configs/q8_a33_tablet_1024x600_defconfig

@@ -21,5 +21,4 @@ CONFIG_SYS_EXTRA_OPTIONS="CONS_INDEX=5"
 # CONFIG_CMD_FLASH is not set
 # CONFIG_CMD_FPGA is not set
 CONFIG_AXP_DLDO1_VOLT=3300
-CONFIG_AXP_ALDO1_VOLT=3000
 CONFIG_USB_MUSB_HOST=y

+ 0 - 1
configs/q8_a33_tablet_800x480_defconfig

@@ -21,5 +21,4 @@ CONFIG_SYS_EXTRA_OPTIONS="CONS_INDEX=5"
 # CONFIG_CMD_FLASH is not set
 # CONFIG_CMD_FPGA is not set
 CONFIG_AXP_DLDO1_VOLT=3300
-CONFIG_AXP_ALDO1_VOLT=3000
 CONFIG_USB_MUSB_HOST=y

+ 2 - 1
drivers/power/Kconfig

@@ -101,7 +101,8 @@ config AXP_DCDC5_VOLT
 config AXP_ALDO1_VOLT
 	int "axp pmic (a)ldo1 voltage"
 	depends on AXP221_POWER
-	default 0
+	default 0 if MACH_SUN6I
+	default 3000 if MACH_SUN8I
 	---help---
 	Set the voltage (mV) to program the axp pmic aldo1 at, set to 0 to
 	disable aldo1.