Pārlūkot izejas kodu

mmc: sdhci: set to INT_DATA_END when there are data

There is no data, it doesn't needs to wait for completing data transfer.
(It seems that it can be removed.)
Almost all timeout error is occured from stop command without data.
After applied this patch, I hope that we don't need to increase timeout value anymore.

Signed-off-by: Jaehoon Chung <jh80.chung@samsung.com>
Acked-by: Lukasz Majewski <l.majewski@samsung.com>
Tested-by: Lukasz Majewski <l.majewski@samsung.com>
Acked-by: Minkyu Kang <mk7.kang@samsung.com>
Jaehoon Chung 9 gadi atpakaļ
vecāks
revīzija
17ea3c8628
1 mainītis faili ar 2 papildinājumiem un 1 dzēšanām
  1. 2 1
      drivers/mmc/sdhci.c

+ 2 - 1
drivers/mmc/sdhci.c

@@ -184,7 +184,8 @@ static int sdhci_send_command(struct mmc *mmc, struct mmc_cmd *cmd,
 		flags = SDHCI_CMD_RESP_LONG;
 	else if (cmd->resp_type & MMC_RSP_BUSY) {
 		flags = SDHCI_CMD_RESP_SHORT_BUSY;
-		mask |= SDHCI_INT_DATA_END;
+		if (data)
+			mask |= SDHCI_INT_DATA_END;
 	} else
 		flags = SDHCI_CMD_RESP_SHORT;