Pārlūkot izejas kodu

watchdog: cadence: Do not stop wdt in probe

Watchdog can be started before probe and u-boot should just take control
over it. That's why do not stop watchdog in probe to cover cases where
watchdog can expire before probe and start.

Signed-off-by: Michal Simek <michal.simek@xilinx.com>
Michal Simek 6 gadi atpakaļ
vecāks
revīzija
0bd83060c2
1 mainītis faili ar 0 papildinājumiem un 2 dzēšanām
  1. 0 2
      drivers/watchdog/cdns_wdt.c

+ 0 - 2
drivers/watchdog/cdns_wdt.c

@@ -224,8 +224,6 @@ static int cdns_wdt_probe(struct udevice *dev)
 {
 	debug("%s: Probing wdt%u\n", __func__, dev->seq);
 
-	cdns_wdt_stop(dev);
-
 	return 0;
 }